The LCU,
a
single coil proportional valve driver tailored for use on EDC
valves, provides precise control of a single coil proportional
valve and enables the user to add ramping and/or dither to minimize
stiction and hysteresis of the valve.
FEATURES:
Control Inputs:
●
Accepts control inputs of -5V to
+5V, 0 to +10V, 4 to 20 mA. or an external potentiometer.
(An external potentiometer and knob are supplied with
every unit.)
Current Capabilities:
●
Current to the coil is regulated
to compensate for coil resistance change, power supply voltage fluctuations
and voltage drops in the wiring going to the coil.
●
The LCU series can drive coils
with low current requirements from 31 to 250 mA.
Pulse Width Modulation (PWM):
●
Variable current is achieved
by high frequency PWM to shift the valve spool.
●
High frequency PWM also provides
excellent current regulation against power supply fluctuation and ripple or
coil resistance change.
●
A PWM% indicator LED turns from
red to green as the output current goes from zero to maximum.
Dither Oscillator:
An optional on-board dither generator provides
dither with adjustable amplitude and factory preset frequency. (Amplitude
can be left at zero should dither not be required.)
Options Available:
●
Weatherpack Connectors with 6-inch
leads.
●
Single-turn
waterproof potentiometer with bezel marked 0 to 100.
ENVIRONMENTAL
●
Operating Temperature: -20 Celsius to +60 Celsius
|