Instructions
-
Click here to open a file as an Excel spread sheet in a separate
window.
-
Complete the I/O Qty Req'd
column to display the HCT product that will support your needs.
-
When you have finished filling in the I/O
Qty Req'd
column, the No. DVC Modules Required column
gives the options for the DVC modules required. You will always
need a DVC5 or DVC10 as the master controller. For example; if the
PWM Outputs indicates you'll need a DVC5 or DVC10 and the Universal / Pulse Inputs indicates you'll need a DVC10, then the
DVC10 is the lowest common denominator, and thus a DVC10 is required.
Each of the I/O requirements are independent functions in the DVC
product, so you don't add up the DVC10's (or expansion modules) on each
line.
-
When you're done filling in the requirements, the
spreadsheet should look something like the example below.
For Example: The lowest common denominator is a
DVC10 +DVC21
or DVC22 or
DVC50.
|
Input/Output Requirements |
I/O
Qty Req'd |
No.
DVC Modules Required |
Specifications |
|
High-Side Outputs |
3 |
DVC5 or
DVC10 |
0 -
3.0A |
|
PWM Outputs |
3 |
2 DVC5's or
DVC10 |
0 -
3.0A |
|
Analog Inputs |
2 |
DVC5 or
DVC10 |
0 to 5
VDC |
|
Universal/ Pulse
Inputs |
1 |
DVC10 |
Analog
or Pulse Input with input electrical selections of:
-1v to 1v,
0v to 5v, 0v to 10v, and 0ma to 20ma |
|
Digital Inputs |
16 |
3 DVC5's or a
DVC10
+ DVC21
or
DVC22
or
DVC50 |
On /
Off Inputs: Sinking; 3 - 32 VDC |
-
You can have up to 16 expansion modules in a
DVC10 configuration.
For additional configurations, contact your local Distributor or
HCT.
Home | Site Map | Contact HCT
|