HGC Gen. Controller
Fan Controllers
HAU Single Coil PWM
LCU Single Coil PWM
HAD Dual Coil PWM
HDU Digital Driver
HDD Digital Driver
Power-Line Driver
HP PWM Valve Driver
PR HP Control
Opto2000

 Hydraulic Fan System Controllers

 

 

DVC Products Valve Driver Cards Hyd. Fan Control Configurator Application Matrix Primer

 

 

Part Number Description Documentation

HFS

Fan driver, thermistors

Cut Sheet

User Manual

HFS-2

Fan driver with reversing, thermistors

Cut Sheet

User Manual

HFS-2Q HFS-2 with WeatherPack connectors Cut Sheet
HFS-J Fan driver with reversing, thermistors or J1939 Cut Sheet User Manual
HFS-J2

Fully programmable dual coil controller w/J1939

Fan Drives

Reference Information

Fan Drives

Temp Sensor Guide

ROI Calculator

 

 

 

Hydraulic Fan System Controller — HFS

 

Application Information:

HFS Fan Controller

HFS Fan Controller

Optimizes fan speed control relative to temperature requirements.

Engines or systems without J1939 capability.

Uni-Directional hydraulic fan drive applications.

OEM, Re-power and Retro-fit opportunities.

On-road and Off-Road suitable mechanical package.

Complimentary controller to expand existing system functionality

 

Product Feature Overview:

Pre-written Windows™ software application, ready for user values.

3 x discrete temperature zone sensor inputs

Additional 2 x discrete switch inputs for fan speed override ( A/C on e.t.c. )

1 x PWM output for any make of proportional valve or pump control.

Open and short circuit cable protection with monitoring

Heavy duty industry standard Deutsch connector.

System ‘error’ indicator LED with blink code.

Unit uses HCT Opto2000 system for set-up and PC communications - Part No: 999-10064.

 

Housing Type:-                         HCT unique ‘encapsulated’ block.

Input Supply Voltage:             10 to 32VDC ( Absolute Maximum )

Input Supply Current:             Valve Current Setting + 200mA Quiescent (Max) 

Command Input Type(s):       3 x 2 wire Thermistor, temperature switch ( software selectable )

                                                         2 x on/off inputs for fan speed over ride ( software selectable ).

Command Input Value(s):     Ohms only ( Max temp = 50  Min temp =  2M)  Additional 2 x Contact closure.

Dither Frequency :                  Software adjustable, ~30 to 250Hz

Housing Material:-                  Black, Polycarbonate

Wire Connections:-                12 way male Deutsch—polarized

Connector type:-                     DT15-12PA

Encapsulation:-                      Flameproof epoxy resin

Mounting:-                               3 x No. 8 ( 5mm ) screws

Temperature range:-            - 40 to +75 ºC ( operational )

NEMA/IP Rating:                     NEMA 6P/68 ( Module only ) derate for connector as required.

CE compliance:                      Pending

 

Electrical Connection Diagram:

 

 


 

Hydraulic Fan System Controller with Reversing — HFS-2

 

 

 

HFS-2 with WeatherPack connectors, P/N: HFS-2Q

HFS-2Q Fan Controller

HFS-2Q Fan Controller

HFS-2 Fan Controller

 1 x 6 way Weatherpack FEMALE for all thermistor inputs and 2 x 4 way Weatherpack’s for power and control functions.

 

Application Information:

Optimizes fan speed control relative to temperature requirements.

Engines or systems without J1939 capability.

Uni or Bi-Directional hydraulic fan drive applications.

OEM, Re-power and Retro-fit opportunities.

Bi-Direction fan direction and speed control

 

On-road and Off-Road suitable mechanical package.

Complimentary controller to expand existing system functionality

 

Product Feature Overview:

Pre-written Windows™ software application, ready for user values.

3 x discrete temperature zone sensor inputs

Automatic or Manually initiated fan reverse cycle

Charge air priority/limiting and noise test features

1 x PWM output for any make of proportional valve or pump control.

1 x ON/OFF output for reverse fan direction valve

1 x ON/OFF output for alarm integration into host system

Open and short circuit cable protection with monitoring

Heavy duty industry standard 2 part or WeatherPak connectors.

System ‘error’ indicator LED with blink code.

Unit uses HCT Opto2000 system for set-up and PC communications - Part No: 999-10064.

 

Housing Type:-                         HCT unique ‘encapsulated’ block.

Input Supply Voltage:             10 to 32VDC ( Absolute Maximum )

Input Supply Current:             Valve Current Setting + 200mA Quiescent (Max) 

Command Input Type(s):       3 x 2 wire Thermistor, temperature switch ( software selectable ) 2 x on/off inputs for fan speed over ride ( software selectable ).

Command Input Value(s):     Ohms only ( Max temp = 50  Min temp =  2M)  Additional 2 x Contact closure

Proportional Output:          1 x PWM up to 3.3A max current

Reverse cycle I/P:               Lo to Hi logic input with software de-bounce

Reverse valve Output:       1 x ON/OFF up to 3.3A max current

Alarm Output:                       1 x ON/OFF up to 3.3A max current

Dither Frequency :                  Software adjustable, ~30 to 250Hz

Housing Material:-                  Black, Polycarbonate

Wire Connections:-                1 x 6 & 1 x 8 Pin Weidmuller or 1 x 6 & 2 x 4 Pin Weatherpack (HFS-2Q)

Encapsulation:-                      Flameproof epoxy resin

Mounting:-                               3 x No. 8 ( 5mm ) screws

Temperature range:-            - 40 to +75 ºC ( operational )

NEMA/IP Rating:                     NEMA 6P/68 ( Module only ) derate for connector as required

CE compliance:                      Pending

 

Electrical Connection Diagram:


 

Hydraulic Fan System Controller with Reversing & J1939 — HFS-J

HFS-J Fan Controller, J1939 Compatible

 

Application Information:

Optimizes fan speed control relative to temperature requirements

Engines or systems with J1939 capability

Uni or Bi-Directional fan feature allows radiator ‘purge’ or ‘De-Ice’

OEM, Re-power and Retro-fit opportunities

On-road and Off-Road suitable mechanical package

Very cost effective ‘all-in-one’ hydraulic fan system controller

 

Bi-Direction fan direction and speed control

 

 

 

 

 

 

 

 

 

 

RS232 Programming Cable, 999-10075

Product Feature Overview:

Pre-written Windows™ software application, ready for user values

3 x temperature zone inputs direct from J1939 bus

2 x discrete inputs for switches OR temperature sensors

1 x PWM output for any make of proportional valve or pump control

2 x ON/OFF outputs for fan reverse valve and  external alarm

J1455 ( load dump) compliant power protection

Heavy duty industry standard Deutsch connector

System ‘error’ indicator LED with blink code

Uses HCT's RS232 programming cable, P/N: 999-10075

 

Housing Type:-                         HCT unique ‘encapsulated’ block.

Input Supply Voltage:             10 to 32VDC ( Absolute Maximum )

Input Supply Current:             Valve Current Setting + 200mA Quiescent (Max) 

Command Input Type(s):       J1939 for charge air, transmission and water temps 2 x additional discrete inputs for switch OR temperature sensors

Command Input Value(s):     Ohms only ( Max temp = 50  Min temp =  2M)  Additional 2 x Contact closure

Proportional Output:             1 x PWM up to 3.3A max current

Reverse cycle I/P:                  Lo to Hi logic input with software de-bounce

Reverse valve Output:          1 x ON/OFF up to 3.3A max current

Alarm Output:                         1 x ON/OFF up to 3.3A max current

Dither Frequency :                  Software adjustable, ~33 to 500Hz

Housing Material:-                  Black, Polycarbonate

Wire Connections:-                12 way male Deutsch—polarized

Connector type:-                     DT15-12PB

RS232 Communications:     4 way Weatherpak connector 

Encapsulation:-                      Flameproof epoxy resin

Bi-Direction fan direction and speed control