High Country Tek, Inc - Home

HAU Single Coil Proportional Valve Driver

 

Can be configured for low Current EDC valves or up to 5.0 Amps output.

 

DVC Products Valve Driver Cards Application Matrix DVC Configurator

 

 

Fan Controllers
Generator Controllers
Power-Line Driver
Opto3000
Plug Top Drivers
HAU Single Coil PWM
LCU Single Coil PWM
HAD Dual Coil PWM

Standard HAU model

HAU with "Q" Option, Weatherpack connectors

The HAU, a single coil proportional valve driver, provides precise control of a single coil proportional valve and can be tailored for use on low current EDC valves such as Sauer-Danfoss™ 90 series, and enables the user to add ramping and/or dither to minimize stiction and hysteresis of the valve.

 

Features of the HAU Single Coil Driver:

 

Rugged Construction:

¨        Fuse protection in series with power to the unit allows inputs and outputs to be hooked up backwards, shorted to each other, grounded or hooked up to +/- 30 volts without harming the unit.

¨        Power Supply input is protected against automotive spikes.

¨        Epoxy potting provides mechanical protection and environmental resistance, including sealing potentiometers against moisture.

Setup and Installation:

¨        Hookup is through an 8-position terminal strip that will accept up to 12-gauge wire.

¨        Labels located next to each of the potentiometers and terminal strip connections simplify hook up and adjustment.

¨        A PWM% indicator LED turns from red to green as the output current goes from zero to maximum.

¨        Minimum input response (dead band elimination), maximum input response, ramp times, dither amplitude and frequency can be adjusted with 10-turn potentiometers for precise control.  Note:  The HAU Driver can be ordered with only the desired controls.

Control Inputs:

¨        Accepts control inputs of -5V to +5V, 0 to +10V,  4 to 20 mA or an external potentiometer. Note:  An external potentiometer and knob are supplied with every unit.

Power Supply:

¨        Power supply voltage range is from 11 to 30 volts. (12 or 24 Volt Systems)

¨        Red power LED indicates sufficient power present for proper operation.

¨        The coil can be driven to within 1.0 volt of the power supply voltage at maximum current.  Note:  Some 10-volt coils require up to 13 volts for full valve shift when hot, making this an important feature for mobile systems.

Current Capabilities:

¨        The HAU Series can drive coils with requirements up to 5 amps.

¨        Current to the coil is regulated to compensate for coil resistance change, power supply voltage fluctuations and voltage drops in the wiring going to the coil.

Pulse Width Modulation (PWM):

¨        Variable current is achieved by high frequency PWM to shift the valve spool.

¨        High frequency PWM also provides excellent current regulation against power supply fluctuation and ripple or coil resistance change.

Dither Oscillator:

¨        An optional on-board dither generator provides dither with adjustable amplitude and factory preset adjustable frequency. Note:  Amplitude can be left at zero should dither not be required.

Options Available:

¨        "Q" Option, Weatherpack Connectors with 6-inch leads.  “Q” option mating connector kit P/N: 999-10169.  See Order Guide for details.

¨        "V" Option, Single-turn waterproof potentiometer with bezel marked 0 to 100.  See Order Guide for details.

ENVIRONMENTAL

·        Operating Temperature:  -20 Celsius to +60 Celsius

 

 

 

Home | DVC Products | Valve Driver Cards | Literature | Documentation | Site Map

 

© Copyright 2009 High Country Tek, Inc. All Rights Reserved.